Closed
Bug 874258
Opened 12 years ago
Closed 11 years ago
Warn if we run shutdown CC more than twice
Categories
(Core :: XPCOM, defect)
Core
XPCOM
Tracking
()
RESOLVED
FIXED
mozilla24
People
(Reporter: mccr8, Assigned: mccr8)
References
Details
Attachments
(1 file, 1 obsolete file)
(deleted),
patch
|
smaug
:
review+
|
Details | Diff | Splinter Review |
What should happen, even with leaks, is that we run the CC twice at shutdown: once to free everything, then another time to confirm that there's nothing to free.
This wasn't actually always true, due to some weirdness that I fixed.
Anyways, warning for this will help figure out which shutdown CC we should log, in leaks like bug 858948.
If I'm feeling a little more brave, I'll make this an assertion.
Assignee | ||
Comment 1•12 years ago
|
||
Let's see if it fails as an assertion.
https://tbpl.mozilla.org/?tree=Try&rev=847064a62b8f
Assignee | ||
Comment 2•12 years ago
|
||
Attachment #751891 -
Attachment is obsolete: true
Attachment #753896 -
Flags: review?(bugs)
Updated•12 years ago
|
Attachment #753896 -
Flags: review?(bugs) → review+
Assignee | ||
Comment 3•11 years ago
|
||
Comment 4•11 years ago
|
||
Status: NEW → RESOLVED
Closed: 11 years ago
Resolution: --- → FIXED
Target Milestone: --- → mozilla24
You need to log in
before you can comment on or make changes to this bug.
Description
•