Closed
Bug 762512
Opened 13 years ago
Closed 12 years ago
Reference image setup for Mountain Lion (Mac OSX 10.8) testing machines
Categories
(Infrastructure & Operations Graveyard :: CIDuty, task, P3)
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: coop, Assigned: kmoir)
References
Details
(Whiteboard: [refplatform][puppet][testing])
With new rev5 minis arriving soon (bug 759466), we will need a Mountain Lion image to put onto the portion of them that will be used as 10.8 testers.
Things that we'll need to verify:
* dongles (or equiv) on all with appropriate resolution
* remote power (PDU)
* unnecessary services turned off (bluetooth, etc)
* puppet
* buildbot startup
Reporter | ||
Comment 1•13 years ago
|
||
Note that we don't need to wait on these new minis to arrive to start this work. We have spare rev5 in staging that could be re-imaged to start this process.
Reporter | ||
Updated•13 years ago
|
Assignee: nobody → kmoir
Assignee | ||
Comment 2•13 years ago
|
||
There is an existing machine that I'm using to test puppet again that could be used - see bug 763487. I think it may need to be updated to a newer version of the 10.8 beta, I'll ask.
Depends on: 763487
Comment 3•13 years ago
|
||
(In reply to Chris Cooper [:coop] from comment #0)
> Things that we'll need to verify:
> * dongles (or equiv) on all with appropriate resolution
EDID101D dongles will be used just like the talos-r4-snow and talos-r4-lion minis in scl1
> * remote power (PDU)
All minis will be install on remotely controllable PDUS. The PDU and Outlet location will be recorded in inventory.
> * unnecessary services turned off (bluetooth, etc)
This will need to be controlled via puppetagain. I would suggest writing a power management module that ensures this.
> * puppet
This will be either baked into the image or installed via scripts in a post re-imaging process (eg. deploy studio workflow)
> * buildbot startup
managed via puppet modules
Updated•13 years ago
|
Comment 4•12 years ago
|
||
I think this is done? We've already reimaged the 10.8 machines with the new base image, and I know that you guys are working on putting them into staging. Should this be R/F, or is there more work to do?
Assignee | ||
Comment 5•12 years ago
|
||
Yes, I think this can be closed. There are a few other tweaks that may be needed but the base image is good.
Status: NEW → RESOLVED
Closed: 12 years ago
Resolution: --- → FIXED
Updated•11 years ago
|
Product: mozilla.org → Release Engineering
Updated•7 years ago
|
Component: Platform Support → Buildduty
Product: Release Engineering → Infrastructure & Operations
Updated•5 years ago
|
Product: Infrastructure & Operations → Infrastructure & Operations Graveyard
You need to log in
before you can comment on or make changes to this bug.
Description
•